VRF Systems

ARV7 AIR CONDITIONING SYSTEM

ARV7 is the latest generation system from AUX. Highly advanced technologically, these devices are the perfect solution for commercial, office, hotel, and residential buildings (ARV Mini). A wide range of indoor units and outdoor modules, which can be configured into systems with a capacity of up to 404 kW, allows for the selection of the right solution for any facility and the implementation of even the most unusual and demanding installations.

eurovent

The ARV7 series has obtained the prestigious Eurovent certification, which guarantees the declared parameters are met.

FEATURES AND FUNCTIONS

Fresh air intake

The possibility of supplying fresh air to the indoor unit. This solution improves indoor air quality, positively affecting the health and comfort of users.

Durable air filter

The indoor unit’s air filter can be easily removed and cleaned. It is resistant to repeated cleaning, significantly extending its lifespan.

Self-cleaning function

Thanks to the comprehensive self-cleaning function, the interior of the air conditioner is kept clean by eliminating moisture and inhibiting the growth of bacteria, mold, and unpleasant odors on the heat exchanger. This ensures a clean and safe environment for users.

Anti-Cold-Air Function

When starting operation in heating mode, the fan of the indoor unit operates at the lowest speed to avoid blowing cold air. The airflow speed is automatically increased as the evaporator temperature rises, up to the set value.

Silent mode

In silent mode, the indoor unit of the air conditioner operates with a reduced sound pressure level, providing comfortable conditions in the room without unnecessary noise.

Follow me Function

The temperature sensor built into the wireless controller allows for measuring the current temperature in the air-conditioned space. The measurement result is sent to the indoor unit, which then automatically adjusts the operating parameters to the conditions in the room.

3D airflow function

The automatic movement of the louvers in both the vertical and horizontal planes allows for the rapid distribution of air in all directions.

Fast cooling / heating

Thanks to the use of inverter technology, the air conditioning system can quickly reach full capacity after startup and ensure the rapid attainment of the desired room temperature.

Auto Auto-Swing louvre movement

The air louvers in the indoor unit move automatically in the horizontal plane – left and right (horizontal swing) or in the vertical plane – up and down (vertical swing), ensuring even distribution of the blown air throughout the room

Independent dehumidification

Thanks to the independent dehumidification function, the air conditioner can reduce the humidity level in the room to an optimal value, enhancing the comfort of the users.

Display activation

Pressing the “Dimmer” button on the controller will turn off the display on the front panel of the indoor unit.

Night mode

When the sleep function is activated, the device increases the set temperature by 1°C per hour during the first two hours in cooling mode (or decreases it at the same rate in heating mode). For the next five hours, it maintains the achieved temperature at a constant level, after which the air conditioner switches off. This ensures maximum comfort during nighttime rest while reducing the device’s energy consumption.

Fins coated with a hydrophilic layer

Fins coated with a hydrophilic layer increase efficiency by 10% and improve condensation speed.

180° sine wave control technology

The DC inverter compressor uses 180° sine wave control technology, ensuring smooth motor operation and a significant increase in efficiency compared to traditional technology. It also contributes to a lower noise level emitted by the outdoor units.

DC inverter technology

DC control, DC compressor, and DC indoor and outdoor unit fan. The use of inverter technology significantly reduces energy consumption compared to standard devices.

Self-diagnosis function

The device monitors malfunctions and shuts down in the event of a failure. An error code indicating the type of fault appears on the indoor unit display (or wired controller), significantly simplifying service procedures.

Cooling at low temperatures

Top-quality components, such as a high-efficiency compressor and a premium heat exchanger, ensure reliable air conditioner operation in cooling mode even at very low outdoor temperatures.

Frost-resistant design

The unique heat exchanger design ensures a higher casing temperature, preventing water accumulation from the defrosting process. This increases heat exchange efficiency and eliminates drainage issues.

Gold-coated heat exchanger fins

The unique gold coating on the heat exchanger surface effectively prevents bacterial growth and improves the unit’s efficiency. It also provides effective protection against corrosion, extending the device’s lifespan.

Fire-resistant electrical box

The device is equipped with a highly fire-resistant electrical box, preventing the risk of fire in the event of an internal short circuit.

Compressor crankcase heater

An additional heating belt raises the compressor oil temperature in winter and prevents water from freezing, improving heat exchange efficiency.

Intelligent defrosting

The intelligent defrosting system ensures nearly uninterrupted operation of the air conditioner in heating mode. The defrost mode is activated only when necessary and only for the time required to defrost the heat exchanger, allowing for more efficient unit operation while heating the room.

24-hour timer

The timer function allows the user to set the exact time for the air conditioner to turn on and off automatically.

Built-in condensate pump

The device is equipped with a high-lift condensate pump.

Two-way condensate drainage

The condensate drainage system can be connected from either the left or right side of the indoor unit, significantly simplifying installation.

Digital display

The digital display panel shows the current operating mode of the device. Parameters such as room temperature and operating mode are clearly displayed in real time.

Washable air filter

The indoor unit’s air filter can be easily removed and cleaned under running water, helping to maintain high device efficiency and air quality.

Automatic restart

In the event of a power outage, the device remembers the last settings and automatically resumes operation with the previously set mode once power is restored.

Wireless controller

The wireless remote control allows for convenient operation of the air conditioner, including turning the device on and off, selecting settings and functions such as operating mode, airflow temperature, fan speed, and airflow direction.

Wired controller

The wired controller is installed on the wall in the room where the air conditioner is located, allowing for easy and convenient operation of the unit.

Central controller

The central controller allows for managing multiple air conditioning systems, enabling control over a larger number of indoor units.

Wi-Fi control module

The Wi-Fi module allows the air conditioner to be controlled via a smartphone, tablet, or computer connected to the internet from anywhere in the world.
TABLE OF COMBINATIONS OF EXTERNAL MODULES
Tableau des Combinaisons de Modules

Résumé des Combinaisons de Modules Externes

HP 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP 34HP 36HP
← Faites défiler horizontalement pour voir toutes les colonnes →

Capacities are given for the following conditions:

Cooling capacity: Indoor temperature 27°C DB/19°C WB; outdoor temperature 35°C DB/24°C WB.
Heating capacity: Indoor temperature 20°C DB; outdoor temperature 7°C DB/6°C WB.
Pipe length: Equivalent pipe length: 7.5 m, level difference: 0 m.

Operation is guaranteed only within combinations up to 130%. If you wish to connect more than 130% of the combination, please contact us to discuss requirements.
Conversion value in an anechoic chamber, measured in a test room. During real operation, these values are usually slightly higher due to environmental conditions.
The above designs and specifications are subject to change without prior notice. Please refer to the technical documentation provided by the sales representative for final specifications.
Sound values are measured in a semi-anechoic chamber, at a distance of 1 m in front of the unit and 1.3 m above the floor.
The above connection types are factory-recommended. Connection types can also be combined according to personal preferences.
Data originates from the AUX laboratory; values may vary depending on test conditions. AUX reserves the right to clarify the data.
All specifications are subject to change by the manufacturer without prior notice.

ARV MINI TECHNICAL PARAMETERS

Capacities are given for the following conditions:

Cooling capacity: Indoor temperature 27°C DB/19°C WB; outdoor temperature 35°C DB/24°C WB.
Tropical cooling capacity: Indoor temperature 27°C DB/19°C WB; outdoor temperature 46.1°C DB.
Heating capacity: Indoor temperature 20°C DB; outdoor temperature 7°C DB/6°C WB.
Pipe length: Equivalent pipe length: 7.5 m, level difference: 0 m.

Conversion value in an anechoic chamber, measured in a test room. During actual operation, these values are usually slightly higher due to environmental conditions.
The above designs and specifications are subject to change without prior notice. Please refer to the technical documentation provided by the sales representative for final specifications.
Data originates from the AUX laboratory; values may vary depending on test conditions. AUX reserves the right to interpret this data.
All specifications are subject to change by the manufacturer without prior notice.

Retour en haut